Industrial Systems

Inverter for sync control system VF66AD/VF66PD

 synchronous 制御システム用InverterVF66AD/VF66PD

These are advanced function models equipped with the sync control function and high-precision drawing control function of the continually evolving VF66SV.

Features/functionality

VF66AD: Absolute sync control

We have commercialized absolute sync control and delivered countless commercial rotary press drive systems. Absolute sync performs rotation commands and motor rotation feedback via numeric data. To achieve a resolution of 33,554,432 Digit/r, SHPC-175-Z is used for the rotation command module and an absolute encoder for the motor.

Absolute rotation command module
SHPC-175-Z
Rotation position commands and rotation speed commands are sent via our proprietary sync communication
For high-precision draw and sync control
Minimizes delay between sections when accelerating/decelerating
RS422
External view of module

External view of module

VF66PD: Incremental sync control

The VF66PD is the successor to the VF64SDS inverter. It applies incremental sync control to the VF64SDS inverter, and we have already delivered countless numbers to our customers. VF66PD’s sync control uses a PG emulator module that generates A, B, Z phases in commands. It uses SHPC-172-Z as a PG emulator module and an incremental encoder for a motor, thereby achieving 76,800 P/r.

PG emulator module
SHPC-172-Z
Generates and outputs rotation position commands using A, B, Z, and phase signals
For high-precision draw and sync control
Minimal delay between sections when accelerating/decelerating
RS422 or optic fiber
External view of module

External view of module

Example application to sectional drive system

This is an example of applying VF66AD to a shaftless rotary press. It achieves a speed control precision of ±0.001% and delivers sectional drive at a precision never before possible. The bottom step represents the speed command for the motor, and the top waveform represents the changes in rotation position error ΔP.

 synchronous 制御の回転位置誤差

Rotation position error in sync control

Specifications

Control method Vector control with speed sensor
Capacity 200 V class: 11 to 180 kW 400 V class: 11 to 1,000 kW
Rated power 200~220 V 380~460 V±10% 50/60 Hz±5%
Output frequency 0.1~400 Hz
Overload capacity 150% for 1 minute 200% for 3 seconds (when at low temperature, 75 kW or more is 150% max)
Network OPCN-1
Input signal Analog ±10 V (2CH) 8 multifunction inputs
Output signal Analog ±10 V (2CH) 3 multifunction outputs

PAGE TOP